omron — A-1-6 Installation and Wiring

Appendices A-1 Designing Example of the Safety Functions for the Pick-and-place Equip- ment Connect the emergency stop pushbutton switch to the Safety Input Unit (N2). A A-1-6 Installation and Wiring Connect the safety light curtain to the I/O power supply and Safety Input Unit (N3). Safety light curtain Safety light curtain Connect the non-contact door switch to the I/O power supply and Safety Input Unit (N4).

A-9 NJ-series Robot Integrated System Startup Guide (O049) Wiring the Emergency Stop Pushbutton Switch NX-SIH400 (N2) T0 T1 Si0 Si1 T0 T1 Si2 Si3 Wiring the Safety Light Curtain Emitter Receiver Emitter Receiver I/O power supply Brown Blue Brown Blue Black White Brown Blue Brown Blue Black White 24 VDC 0 V NX-SIH400 (N3) Control output 1(OSSD 1) Si0 Control output 2(OSSD 2) Si1 Control output 1(OSSD 1) Si2 Control output 2(OSSD 2) Si3 NX-SIH400 (N3) Si0 Si1 Si2 Si3 Wiring the Safety Door Switch