3 Implementation Example of Static Pick-and-place Equipment 3-3 Programming and Simulation Procedures For information on global variables to register, refer to Sequence Control Program on page 3-3 if the system is controlled by the sequence control program or Sequence Control Program on page 3-11 when it is controlled by the V+ program. The global variable is registered. Creating Ladder Diagram Programs 3 This section describes how to create the ladder diagram programs. 3-3-3 Creating a Sequence Control Program 1 Right-click Program0 under Programming - POUs - Programs in the Multiview Explorer and select Rename from the menu. This allows you to edit the name of the sequence control program.
2 Enter the name of the sequence control program. The name of the sequence control program is changed. 3 Double-click the section to edit. The variable table and Ladder Editor are displayed in the Edit Pane. 3-25 NJ-series Robot Integrated System Startup Guide (O049)