omron — Teach Restrict Verification Utility

Chapter 6: Maintenance The default speed is 10, but you can change that speed with this screen's speed control. l You can click Move to Ready, to move the robot to the Ready position. The robot will move each joint, in succession. It will generate an over-speed condition for each, and verify that the hardware detected the over-speed condition. 4. Click Next, to proceed to the Manual Mode Procedure. If the Automatic Mode Procedure fails, you will not be allowed to proceed with the Manual Mode. Manual Mode Procedure The manual mode of this verification requires the use of an Adept pendant. For this verification, the Front Panel keyswitch must be in Manual mode. 1.

From the Introduction screen, click Next. l Set the pendant to Joint mode. l Set the pendant manual control speed to 100. 2. Click Next. 3. Using the pendant, jog any of the robot's joints until power is disabled. This indicates that the Teach Restrict function is working. 4. Click Next. The results of the verification will be displayed. 5. Click Finish. 6. Reset the Front Panel keyswitch to Auto mode. Adept Hornet 565 Robot User's Guide, User’s Guide, Rev A Page 121 of 142