Orion-Tr Tr Smart DC-DC Charger — 5.3. Setup for Euro 6 vehicles

Orion-Tr Smart DC-DC Charger Isolated 24|12; 24|24; 24|48: 16 to 35V 48|12; 48|24; 48|48: 32 to 68V Setup input voltage lock-out : Input voltage lock-out is the minimum level at which charging is allowed; below this level, charging stops immediately. Default (in charger mode): lock-out: 12.5V / restart: 12.8V. Default (in power supply mode): lock-out: 10.5V / restart: 12V. When ‘forced charging’ is enabled, current will be drawn from the starter battery if the engine is not running. Setting the lock-out level very low can result in a depleted starter battery. To set up input voltage lock-out, two criteria are important: Minimum alternator voltage :

A smart alternator can operate at very low alternator voltage ( accelerates. This low voltage is allowed during tshutdown as shown in “engine shutdown detection sequence 3→4”. If charging must remain enabled during this period, the lock-out level must at least be set below the minimum alternator voltage. If the low voltage period exceeds tshutdown charging will be disabled on engine shutdown detection. Voltage drop across the input cable: As seen in “engine shutdown detection sequence 1→3”, V IN will be lowered by Vcable. When the alternator voltage drops fast (smart alternator), the charge control needs some time to reduce the charge current and keep V IN at V shutdown .

During this time V cable must not trip the voltage lock-out. Therefore, the lock-out value should be: V lock-out shutdown – V cable. Example: Calculate the input cable voltage drop: Distance between starter battery and charger: 5m. V shutdown = 13.1V. Recommended wire gauge: 16mm2. Cable resistance: ~1.1mΩ/m @20°C, thus R cable = 1.1mΩ x 10m (2x 5m) = 11mΩ. A 12|12-30A Smart Charger will draw about 35A from the input when running at full capacity, resulting in: V cable = 11mΩ x 35A = 385mV. V lock-out ≤ V shutdown – V cable = 13.3V – 385mV ≈ 12.9V. Cable connections, external fuses, temperature, etc., influence the total cable resistance. 5.3.

Setup for Euro 6 vehicles Euro 6 vehicles use a smart alternator that is managed by the vehicle. While driving, the alternator management system decides whether the alternator is needed, based on the electrical demand of the vehicle and on how much energy can be recovered during braking. As a result, the charge voltage is not constant: it can vary roughly between 12.5V and 15V in a 12V system, and the alternator can be switched off completely for a while. When the alternator is switched off, the voltage at the starter battery falls back to the static battery voltage (~12.6 V).

The engine shutdown detection reads that voltage and can conclude that the engine has stopped, even though the vehicle is still driving. During this phase, the will not charge, potentially resulting in an undercharged auxiliary battery. The voltages mentioned in this section apply to 12V input models. For 24V input models, scale the values accordingly. The alternator management system also reacts to the electrical demand in the vehicle. When enough loads are present, the alternator produces at least a float-level voltage (~13.8V), which the engine shutdown detection recognises without difficulty.

If the base load in the system is sufficiently high, the alternator remains active for most of the drive and the automatic detection works well. Whether this happens depends on the vehicle and on the installation, so the engine shutdown detection sometimes needs fine-tuning. Four settings are available for this in the VictronConnect App: the start voltage, the delayed start voltage, the delayed start voltage delay and the shutdown voltage. See the Engine shutdown detection setup with VictronConnect [12] section for a description of each setting.

Lowering the start and shutdown voltages makes the detection tolerate the lower charge voltages of a smart alternator, at the cost of a smaller margin above the static battery voltage. Be aware that charging strategies differ from vehicle to vehicle, even within the same brand and model. Owners of the same vehicle model may find that some can successfully utilise engine shutdown detection, while others experience undercharged auxiliary batteries. Page 13 Automatic engine shutdown detection