Orion-Tr Tr Smart DC-DC Charger — 8. Specifications

Orion-Tr Smart DC-DC Charger Isolated Page 27 Specifications Orion-Tr Smart DC-DC Charger Isolated 360 – 400 Watt 12/1 2-30 (360 W) 12/2 4-15 (360 W) 12/4 8-8 (360 W) 24/1 2-30 (360 W) 24/2 4-17 (400 W) 24/4 8-8,5 (400 W) 48/1 2-30 (360 W) 48/2 4-16 (380 W) 48/4 8-8 (380 W) Output noise 2 mV rms Cont. output current at nominal output voltage and 40°C 30 A 15 A 8 A 30 A 17 A 8.5 A 30 A 16 A 8 A Maximum output current (10 s) at nominal output voltage minus 20% 40 A 25 A 15 A 45 A 25 A 15 A 40 A 25 A 15 A Short circuit output current 60 A 40 A 25 A 60 A 40 A 25 A 60 A 40 A 25 A Cont. output power at 25°C 430 W 430 W 430 W 430 W 480 W 480 W 430 W 430 W 430 W Cont.

output power at 40°C 360 W 360 W 360 W 360 W 400 W 400 W 360 W 380 W 380 W Efficiency 87% 88% 89% 88% 89% 89% 87% 89% 89% No load input current Standby current Less than 1 mA Galvanic isolation 200 V dc between input, output and case Operating temperature range -20 to +55° C (derate 3% per °C above 40° C) Humidity Max. 95% non-condensing DC connection Screw terminals Maximum cable cross-section 16 mm² AWG6 Weight 12 V input and/or 12 V output models: 1.8 kg (4 lb) Other models: 1.6 kg (3.5 lb) Dimensions hxwxd 12 V input and/or 12 V output models: 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch) Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) Standards:

Safety Emission Immunity Automotive Directive EN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-5 1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does not decrease) increases by the same percentage. Note 1) The VictronConnect App will not display current in or current out. Note 2) The Orion-Tr Smart DC-DC Charger Isolated is not equipped with a VE.Direct port.