Orion-Tr Smart DC-DC Charger Non-Isolated 4.5. Connection setup for DC-DC power supply mode 1. Disconnect the remote on/off; remove the wire bridge or unplug the terminal block. 2. Connect the input supply cables. 3. Open the VictronConnect App to set up the product, see Power Supply Mode [27] (always adjust the output voltage before connecting in parallel or connecting a battery) . 4. Connect the load. The Orion is now ready for use as a power supply. 5. Reconnect the remote on/off to activate the product. Figure 1: Typical connection setup as DC-DC power supply 4.6. Connection setup for charger mode 2. Connect the input supply cables. 1.
Disconnect the remote on/off; remove the wire bridge or unplug the terminal block. 3. Open the VictronConnect App to set up the product, see Charger Mode [28] (always set up the correct charger algorithm before connecting a battery) . 4. Connect the battery to be charged. 5. Reconnect the remote on/off to activate the product. Page 7 Installation