Orion-Tr Tr Smart DC-DC Charger Non-Isolated — 9.3.2. Charger Mode - Battery Settings

Orion-Tr Smart DC-DC Charger Non-Isolated 9.3. Settings VictronConnect allows the user to change and adjust several different settings from the Orion Smart. This is done through the settings option that can be accessed by clicking the icon on the right top corner of the screen. The settings options are different according to the operation mode that is selected. 9.3.1. Charger Mode When on Charger Mode, these are the available settings. Function allow to choose between “Charger” or “Power supply”. When charger mode is selected, the Orion Smart will follow the three state charge algorithm. For more information about the charge algorithm, please read the Orion Smart manual .

Battery settings allow to change the battery settings in order to adjust the absorption voltage, float voltage and others to fit the battery being charged. The battery setting is explained better on the next item. Input voltage lock-out allow to choose between two thresholds. One to set the lock-out and another one to reset it. Normally, a minimum 0.5V (for 12V input Orion Smart) difference is used for a better performance. The protection can still be disabled if desired by the user. For more information about the input voltage lock-out, please read the Orion Smart manual . Engine shutdown detection allow to choose between two thresholds.

One to set the detect the engine shutdown and another one to detect when it is running. Normally, a minimum 0.2V (for 12V input Orion Smart) difference is used for a better performance. The engine shutdown detection can still be disabled if desired by the user. For more information about the engine shutdown detection, please read the Orion Smart manual . 9.3.2. Charger Mode - Battery Settings Charger enabled Toggling this setting turns the Orion Smart off. The batteries will not be charged. Charger settings - Battery preset Battery preset allows to select the battery type; accept factory defaults; or enter your own preset values to be used for the battery charge algorithm.

The Absorption voltage, Float voltage, Bulk time limit, Re-bulk voltage offset, Adaptive absorption time and Absorption time, settings are all configured to a preset value - but can be user-defined. User-defined presets can be stored in the preset library - in this way installers will not have to define all the values each time they are configuring a new installation. By selecting Edit Presets, custom parameters can be set as follows: Absorption voltage VictronConnect - Orion Smart DC-DC Charger Page 28