Downloaded from https://www.everyspec.com TOP 1-2-621 6 February 2009 c. Temperature Conditioning. If temperature conditioning of the test article is required, verify operation of the chamber and the temperature data acquisition equipment. Place the UUT inside the climatic chamber. Install the necessary temperature measuring devices (thermocouples) on the test item and in the chamber. Start temperature conditioning by raising the temperature to the high temperature limit within the required period of time, i.e., at the specified temperature rate of change. Hold the chamber temperature until stabilization occurs.
Stabilization has occurred when the slowest responding thermocouple of the test item is within 3єC (5єF) of the specified temperature. Once stabilized, quickly remove the UUT from the chamber, emplace in the test area, and begin the sand/dust test as described above. If portable conditioning units are employed at the test area, then remove the conditioning units and start the sand/dust test described above. Repeat the above process for each face of the test item. 5. DATA REQUIRED. a. Test item S/N, date, and test item configuration. b. Test equipment descriptions. c. Instrumentation locations. d. Results of pre/post test visual inspections, in particular sand and dust ingress. e.
Meteorological conditions (air temperature, RH, wind speed and direction) f. Sand and dust particle size distribution and concentration. g. Applied wind velocity, item orientation, test item temperature versus time, and exposure duration for each exposure/face. h. Test record of significant observations and anomalies to include descriptions of any failures in the test item or test equipment. i. Documentary photographs/video of the test/test setups. j. Test item inspection and performance test results. 6. PRESENTATION OF DATA. Test data may be presented in the form of plots, checklists, or tables similar to those shown in Appendix B. 11