PanelScan Integration Guide Camera Testing Once the Basler Software is installed and the IP addresses are set, the camera can be tested. Go to Start > Basler > Pylon 5 Camera Software Suite > Pylon Viewer (x64) . The cameras should automatically be detected by the software and show up in the camera list. • Click each camera in turn. • Click on the camera in the Features section. • Navigate to Acquisition Controls and set the Exposure Time (Raw) to 1,700 μs . • Set the camera lens aperture to 8.0 . • Click the Continuous Shot button in the camera menu or in the menu toolbar. • Zoom to fit so you can see entire 6K across of image buffer. • Observe the image.
Shine a light at the camera to verify that it is capturing images. An example of the Pylon Viewer user interface is shown here: 10 Copyright © 2019 Omron Microscan Systems, Inc.