Delta · PMC · 11 стр.
pmc 24v150w1aa Datasheet
Related manuals
Document text
Panel Mount Power Supply 24V 150W 1AA Features RoHS compliant 2 years warranty Universal AC inpu Overload protection Efficiency> 86% Typ. Over voltage protection Expected life time: 10 years Over temperature protection Ease of wire connection to Terminals Model No. PMC 24V 150W 1AA Weight: 0.48kg Size: 178mm x 97mm x 38mm (H x W x D) Full aluminum casing for lightweight and corrosion resistant handling Description The new Panel Mount Power Supply PMC24V150W1AA is the latest offering from one of the World’s No.1 Power Supply Company.
The product offers a nominal output voltage of 24V, a wide temperature range from -10°C to 75°C and a minimum holdup time of >20ms.The state-of-the-art design is made to withstand harsh industrial environments. The rugged, compact design aluminum case is shock and vibration resistant according to IEC60068-2-6. The 150 watts PMC panel mount power supply provides over voltage, overload and thermal protection. Due to the wide input voltage range from 85 to 264 Vac, the Delta’s PMC panel mount power supply is high line input voltage usable, multiple output terminals for fast wiring and easy installation.
www.DeltaPSU.com 1 INPUT SPECIFICATION Input Voltage (Nominal) 100 - 240Vac Input Voltage range 85 - 264Vac Input Frequency (Nominal) 50 - 60Hz Input Frequency range 47 - 63Hz DC Input Voltage (Nominal) 125 - 250Vdc DC Input Voltage Range 120 - 375Vdc Input Current Efficiency > 86% @ 115Vac & 230Vac Inrush current (Cold Start) Leakage Current OUTPUT SPECIFICATION Output Voltage (Nominal) 24 Vdc Output Voltage Tolerance +/- 2% (Initial set point tolerance) Output Voltage Adjust Range 22 - 28 Vdc Line Regulation Load Regulation Residual Ripple (PARD), 20MHz BW Output Current (Nominal) 6.25 A Power Derating above 50°C Derated Linearly 2.5% / °C Rise Time Start-Up Time Hold-Up Time > 15ms @ 115Vac, > 80ms @ 230Vac (100% load, 25°C) Dynamic Response (Overshoot & +/-5% @ 0% - 100% load Undershoot O/P Voltage) Startup with capacitive loads 8,000µF @ nominal input & nominal O/P voltage 24V (25°C)
Panel Mount Power Supply 24V 150W 1AA Device Description: 1. Input & Output terminal block connector 2. DC Voltage adjustment potentiometer 3. DC OK Control LED (green) Mechanical Drawing: www.DeltaPSU.com 2 MECHANICAL SPECIFICATION Dimension 178 mm X 97 mm X 38 mm (H x W x D) Weight 0.48kg Cooling System Convection Input and Output Terminal Terminal Block with screw M3.5 x7 pins (rated 300VAC, 15A) Output Indicator Green LED (DC OK) Casing Aluminium
Panel Mount Power Supply 24V 150W 1AA Block Diagram: www.DeltaPSU.com 3
Panel Mount Power Supply 24V 150W 1AA Over Load Protection Over Voltage Protection The Power Supply is provided with an overload The Power Supply is protected by Over voltage in the protection (OLP/OCP) function which protects the power event that power supply feedback circuit fails the output supply from possible damage by over current. voltage will not be > 32V, +10% under any Line/Load Additionally power supply also has over temperature protection (OTP) in case the over load condition persists and operating ambient conditions.
The unique feature about this over voltage protection (OVP) is that power for a longer duration and is below the overload trigger supply doesn’t shut down but goes Hicc-up mode (Auto point but > 100% load. recovery) which is 32V, +/-10%. The power supply output voltage will recover back to 24Vdc once the fault Typically the over load current (I OL ) is > I SURGE (120%) output voltage will start drooping down when the power condition is removed. Short Circuit Protection supply reaches max power limit and will run into bouncing mode when the output reaches UVLO (under voltage The Power Supply also has a short circuit protection point).
The output voltage will recover automatically when the overload condition is removed. which is in line with the overload protection and activates whenever there is a short across the output Over Temperature Protection voltage, output goes in bouncing mode and remains until the fault is removed. Additionally power supply also has over temperature protection (OTP) as mentioned above this OTP comes into picture when the over load condition persists for a longer duration and the output current level is below the overload trigger point but > 100% load. www.DeltaPSU.com 4 PROTECTION 32V +10%/-10%, SELV output, Hicc-up Mode, Non-Latching Over Voltage Protection (Auto recovery).
> 120% of rated load current, Hicc-up Mode, Non-Latching Over Load, Over Current Protection (Auto recovery). Over Temperature Protection recovery). Hicc-up Mode, Non-Latching, (Auto-recovery when the fault is Short Circuit Protection removed).