Model Numbering
TECHNICAL DATASHEET PMT Panel Mount Power Supply 24V 350W 1 Phase / PMT-24V350W1AK PMT Highlights & Features AC input range selectable by switch Full Aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit MTBF > 700,000 hrs. as per Telcordia SR-332 Short Circuit / Overvoltage / Overload / Over Temperature Protections Safety Standards CB Certified for worldwide use Model Number: PMT-24V350W1AK Unit Weight : 0.82 kg Dimensions (L x W x D): 215 x 115 x 50 mm General Description The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta.
PMT-24V350W1AK offers a nominal output voltage of 24V with a wide operating temperature range from -10°C to +70°C and can withstand shock and vibration (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de- rating from 100Vac to 132Vac & 180Vac to 264Vac.
Model Information PMT Panel Mount Power Supply Model Numbering 1 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev. 00) Model Number Input Voltage Range Output Voltage Output Current PMT-24V350W1AK 90-132Vac, 180-264Vac (Selectable by Switch) 24Vdc 14.6A CC Code PM T – 24V 350W 1 A K □ Panel Mount Product Type T – Enclosed Output Voltage Output Power Single Phase No PFC Connector Type K – Front Face Blank – Without connector cover A – With connector cover
Mechanical
TECHNICAL DATASHEET PMT Panel Mount Power Supply 24V 350W 1 Phase / PMT-24V350W1AK Specifications Input Ratings / Characteristics Output Ratings / Characteristics Mechanical 2 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev.
00) Nominal Input Voltage 100-120Vac, 200-240Vac (Selectable by Switch) Input Voltage Range 90-132Vac, 180-264Vac (Selectable by Switch) Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current Efficiency at 100% Load > 87.0% @ 230Vac Max Inrush Current Leakage Current Nominal Output Voltage 24Vdc Output Voltage Tolerance ± 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 20.0-26.4Vdc Output Current 14.6A Output Power 350W Line Regulation ± 0.5% typ. Load Regulation ± 0.5% typ.
PARD (20MHz) Rise Time Start-up Time Hold-up Time > 16ms @ 115Vac, > 20ms @ 230Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 10-50% load and 50-100% load Start-up with Capacitive Loads 8,000µF Max Case Chassis Aluminium Case Cover Aluminium Dimensions (L x W x D) 215 x 115 x 50 mm Unit Weight 0.82 kg Indicator Green LED (DC OK) Cooling System Forced Cooling Terminal M3.5 x 9 Pins (Rated 300V/20A) Wire AWG 20-12
Safety Standards / Directives
TECHNICAL DATASHEET PMT Panel Mount Power Supply 24V 350W 1 Phase / PMT-24V350W1AK Environment Protections *PE: Primary Earth Reliability Data Safety Standards / Directives 3 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev. 00) Surrounding Air Temperature Operating -10°C to +70°C Storage -25°C to +85°C Power De-rating > 50°C de-rate power by 2.5% / °C Operating Humidity Operating Altitude 5,000 Meters Shock Test (Non-Operating) IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total Vibration Operating IEC 60068-2-6, Sine Wave:
10Hz to 150Hz @ 25m/S² (2.5G peak); 90 min per axis for all X, Y, Z direction Non-Operating IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20 min per axis for all X, Y, Z direction Pollution Degree 2 Overvoltage Overload / Overcurrent Over Temperature Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) Short Circuit Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection MTBF > 700,000 hrs. as per Telcordia SR-332 Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C) Electrical Safety TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No.
60950-1, CB scheme to IEC 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac Input to Ground 1.5KVac Output to Ground 0.5KVac
EMC
TECHNICAL DATASHEET PMT Panel Mount Power Supply 24V 350W 1 Phase / PMT-24V350W1AK EMC *Fulfills tested conditions 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev. 00) EMC / Emissions CISPR 22, EN 55022, EN 55011, FCC Title 47: Class B Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge:
8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 10A/Meter Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Harmonic Current Emission NA Voltage Fluctuation and Flicker* IEC/EN 61000-3-3