ebm-papst Mulfingen GmbH & Co. KG Bachmьhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com 1. SAFETY REGULATIONS AND NOTES Please read these operating instructions carefully before starting to work with the device. Observe the following warnings to prevent malfunctions or physical damage to both property and people. These operating instructions are to be regarded as part of this device. If the device is sold or transferred, the operating instructions must accompany it. These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. CONTENTS 1 1.
SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1 1.1 Levels of hazard warnings These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations: 1 1.2 Staff qualification 1 1.3 Basic safety rules 1 1.4 Electrical voltage DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with the measures is mandatory. 2 1.5 Safety and protective functions 2 1.6 Electromagnetic radiation 2 1.7 Mechanical movement WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Exercise extreme caution while working. 2 1.8 Emission 2 1.9 Hot surface 2 1.10 Storage CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 2 1.11 Disposal 3 2. PROPER USE NOTE A potentially harmful situation can occur and, if not avoided, can lead to property damage. 4 3. TECHNICAL DATA 4 3.1 Product drawing 5 3.2 Nominal data 1.2 Staff qualification 5 3.3 Technical features The device may only be transported, unpacked, installed, operated, maintained and otherwise used by qualified, trained and authorised technical staff.
Only authorised specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation. 5 3.4 Mounting data 5 3.5 Transport and storage conditions 5 3.6 Electromagnetic compatibility 6 4. CONNECTION AND START-UP 1.3 Basic safety rules 6 4.1 Connecting the mechanical system 6 4.2 Connecting the electrical system Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. Observe the following when working on the unit:
6 4.3 Connection of the cables Translation of the original operating instructions 7 4.4 Connection screen ; Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 8 4.5 Checking the connections 8 4.6 Switch on device 1.4 Electrical voltage 8 4.7 Switching off the device ; Check the electrical equipment of the device at regular intervals, refer 8 5. INTEGRATED PROTECTIVE FUNCTIONS ; Replace loose connections and defective cables immediately. to chapter 6.2 Safety test. 9 6.
MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES DANGER Electrical load on the device Risk of electric shock 9 6.1 Cleaning 9 6.2 Safety test →Stand on a rubber mat if you are working on an electrically WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock charged device. →Wait five minutes after disconnecting the voltage at all poles before opening the device. ebm-papst Mulfingen GmbH & Co. KG · Bachmьhle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com R3G220-RC05-03 Operating instructions Item no. 51016-5-9970 · ENG · Revision 82086 · Release 2014-11-04 · Page 1 / 10
CAUTION In the event of failure, there is electric voltage at the rotor and impeller The rotor and impeller are base insulated. →Do not wear any loose clothing or jewellery while working on rotating parts. →Protect long hair by wearing a cap. →Do not touch the rotor and impeller once they are installed. 1.8 Emission CAUTION If control voltage is applied or a speed setpoint is stored, the motor automatically restarts, e.g. after a power failure. Danger of injury WARNING Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise. Danger of noise-induced hearing loss →Keep out of the danger zone of the device.
→Take appropriate technical safety measures. →When working on the device, switch off the mains →Protect operating personnel with appropriate safety supply voltage and secure the latter from being switched on again. →Also observe the requirements of local agencies. equipment, e.g. hearing protection. →Wait until the device stops. →After working on the device, remove any used tools or 1.9 Hot surface other objects from the device.
CAUTION High temperature at the electronics enclosure Danger of burn injuries 1.5 Safety and protective functions DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are sucked into it. →Ensure that sufficient protection against accidental contact is provided. 1.10 Storage ; Store the device, partially or fully assembled, in a dry and →Operate the device only with a fixed and isolating safety protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade detaching at maximum speed.
weatherproof manner in the original packing in a clean environment. ; Protect the device from environmental impacts and dirt until the final installation. →The device is a built-in component. You, the owner/ ; We recommend storing the device for a maximum up to one year to guarantee proper operation and longest possible service life. operator, are responsible for providing adequate protection for the device. ; Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned. →Shut down the device immediately if you detect a missing or ineffective protective feature.
; Maintain the storage temperature, see 1.6 Electromagnetic radiation chapter 3.5 Transport and storage conditions. Interference from electromagnetic radiation is possible, e.g. in conjunction with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, appropriate shielding measures have to be taken by the user. 1.11 Disposal When disposing of the device, please comply with all relevant requirements and regulations applicable in your country. Translation of the original operating instructions NOTE Electrical or electromagnetic interferences after integrating the device in installations on the customer's side.
→Verify that the entire setup is EMC compliant. 1.7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured. →Secure the device against accidental contact. →Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. ebm-papst Mulfingen GmbH & Co. KG · Bachmьhle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com R3G220-RC05-03 Operating instructions Item no.
51016-5-9970 · ENG · Revision 82086 · Release 2014-11-04 · Page 2 / 10
2. PROPER USE The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. Proper use also includes: Moving air with a density of 1.2 kg/mі. Using the device in accordance with the permitted ambient temperature, see chapter 3.5 Transport and storage conditions and chapter 3.2 Nominal data. Operating the device with all protective features in place. Minding the operating instructions.
Improper use Using the device in the following ways is particularly prohibited and may cause hazards: Operating the device with an imbalance, e.g. caused by dirt deposits or icing. Moving air that contains abrasive particles. Moving highly corrosive air, e.g. salt spray mist. Exceptions are devices that are intended for salt spray mist and protected accordingly. Moving air that contains dust pollution, e.g. suctioning off saw dust. Operating the device close to flammable materials or components. Operating the device in an explosive atmosphere. Using the device as a safety component or for taking on safety- related functions.
Operation with completely or partially disassembled or modified protective features. In addition, all application options that are not listed under proper use. Translation of the original operating instructions ebm-papst Mulfingen GmbH & Co. KG · Bachmьhle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com R3G220-RC05-03 Operating instructions Item no. 51016-5-9970 · ENG · Revision 82086 · Release 2014-11-04 · Page 3 / 10
3. TECHNICAL DATA 3.1 Product drawing All measures have the unit mm. Translation of the original operating instructions ebm-papst Mulfingen GmbH & Co. KG · Bachmьhle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com R3G220-RC05-03 Operating instructions 1 Accessor y part: Inlet nozzle 09609-2-4013, not included in the standard scope of delivery 2 Connecti on line PVC 3G AWG20, 3x brass lead tips crimped 3 Control li ne PVC 4X AWG22, 4 x brass lead tips crimped 4 Depth of screw max. 5 mm Item no. 51016-5-9970 · ENG · Revision 82086 · Release 2014-11-04 · Page 4 / 10