oven — 7.1 Sequence of setup

Since the FDP and DP parameters set restrictions on each other (the number of displayed digits after the decimal point in the counting results can not be larger than the number of digits after the decimal point of the entered multiplier), editing of parameters FDP , DP , F should be performed in the following sequence: • to increase the number of displayed digits after the decimal point (decimal point offset to the left): ◦set parameter FDP ; ◦set parameter F ; ◦set parameter DP ; • to decrease the number of displayed digits after the decimal point (decimal point offset to the right): ◦set parameter DP ; ◦set parameter FDP ; ◦set parameter F .

Structure of the RS-485 configuration settings menu and sequence of pressing the buttons for setup is shown in Figure 7.3 . NOTICE The list of configurable parameters of the device and their possible values is shown in Appendix A . 40