Delta Electronics — 5.2.10 16-bit Counters

AS Series Operation Manual T1 T2 T1+T2=10sec SV: K100 T250 (PV) Y0.0 C. Timer used in the function block Use the T412–T511 timers for the function block or the interrupt. _5 When the instruction TMR or END is executed, the timer used in the functional block begins to count. When the value of the timer matches the timer setting value, the output coil is ON. If you use the general-purpose timer is used in the function block or the interrupt, and the functional or interrupt is not executed, the timer cannot count correctly.

5.2.10 16-bit Counters  Characteristics of the 16-bit counter 5-16 0.0 Item 16-bit counter Type General type Number C0–C511 Direction Counting up Setting value 0–32,767 Specificying the counter setting value The setting value can be either the constant or the value in the data register. Change of the current value The counter stops counting when the value of the counter matches the setting value. Output contact The contact is ON when the value of the counter matches the setting value.