AS Series Operation Manual _2 *1: If the input signal exceeds the hardware input limit, the module only shows the maximum value. If the input signal is below the lower limit, it only shows the minimum value. *2: If the input signal exceeds the hardware input limit, it also exceeds the conversion limit and a conversion limit error appears. For example in the voltage input mode (4 mA to 20 mA), when the input signal is 0 mA, exceeding the hardware upper limit, it also exceeds the conversion upper limit. The module uses the upper limit value (-384) as the input signal and a conversion limit error appears. *3: If an input signal exceeds the absolute range, it might damage the channel.
AS04DA-A Electrical specifications 2-37 Analog-to-Digital Current Input Conversion Rated Input Range ±20 mA 0 mA–20 mA 4 mA–20 mA K-32000 ~ K+2000 K0 ~ K32000 K0 ~ K32000 Rated Conversion Range Hardware Input -20.24 mA ~ 20.24 mA -0.24 mA ~ 20.24 mA 3.81 mA ~ 20.19 mA Limit*1 K-32384 ~ K32384 K-384 ~ K32384 K-384 ~ K32384 Conversion Limit*2 Room Temperature: ±0.2% ; Full Temperature Range:
±0.5% Error Rate 16 bits Hardware Resolution 250Ω Input Impedance Absolute Input ±32 mA Range*3 Module name AS04DA-A Number of outputs Four Digital-to-analog Voltage output/Current output conversion Supply voltage 24 VDC (20.4 VDC–28.8 VDC) (-15%–+20%) Connector type Removable terminal block Conversion time 2 ms/channel An analog circuit is isolated from a digital circuit by a digital integrated circuit/an optocoupler, but the analog channels are not isolated from one another. Isolation between a digital circuit and a ground: 500 VDC Isolation between an analog circuit and a ground: 500 VDC Isolation between an analog circuit and a digital circuit:
500 VDC Isolation between the 24 VDC and a ground: 500 VDC Isolation Weight 145 g