RIEVTECH — RIEVTECH STUDIO SOFTWARE MANUAL(2.0 Version).docx

RIEVTECH STUDIO SOFTWARE MANUAL l Status No. The range of the status number is 1~256. Each status corresponds to the value of the word address.When many statuses satisfy the condition at the same time, only the status with the minimum value will be effective. l Condition Ш Range The status content (value) will be determined according to the value of the combined bits. The comparison operation includes “ > ” , “ ” , “ >= ” , “ ” , “ == ” and “ != ” . The logic operation can be “ AND ” , “ OR ” or “ None ” . l Flash Mode It includes three modes: “ None ” , “ Blink Text ” and “ Blink Picture ” . You can select each status in left table and then set the flash mode for the status selected.

Ш None It means no flashing. Ш Blink Text Text can flash in a frequency. Ш Blink Picture Picture can flash in a frequency. l Flash Freq. Picture or text will flash in a designated frequency. The frequency can be a multiple of 0.1 second. Detailed attribute information of the current component can be seen in the table at the left bottom. 157