omron — Battery Safety Information

Chapter 2: Operational Safety Battery Safety Information WARNING: FIRE RISK: The mobile robots use lithium ion batteries. If a battery is ruptured and exposed to water, it may ignite or explode. If the battery is found to be leaking, do not expose to water. If possible, sub- merge in mineral oil and contact your local Omron Representative. Effective April 1, 2016, IATA regulations (UN 3480, PI 965) require that air-shipped lithium ion batteries must be transported at a state of charge not exceeding 30%. To avoid total discharge, fully charge the battery immediately upon receipt. Safety Precautions l Store batteries upright at 5 to 45°C (41 to 113°F) for up to one month.

Store at 20 to 25°C (68 to 77°F) for up to one year. l Do not expose to water. l In case of fire, use a type D extinguisher: foam, dry chemical, or CO 2 . Maintenance Every six months: l Inspect battery for damage or leaks. l Place battery on a charger and allow to fully charge. 18393-000 Rev H Mobile Robot LD Safety Guide 23