Downloaded from https://www.everyspec.com MIL-HDBK-1001/5A 5.2 General Requirements 5.2.1 Felts. Organic felts are highly vulnerable to moisture-induced deterioration; use the more durable fiber glass felts. Organic felts can, however, be used in temporary membranes that are to be removed or in coal-tar pitch membranes. 5.2.2 Modified Bitumen Flashing. Single-ply modified bitumen sheets may be used for flashing material. 5.2.3 Compatibility. Check with the manufacturer of built-up roofing membrane and flashing materials to assure that proposed roof system and materials are compatible with roof deck, vapor retarder, insulation, and geographic location.
5.3 Membrane Design Recommendations 5.3.1 Bitumen Slope Limits Require bitumen manufacturer to provide equiviscous temperature (EVT) stenciled on every bitumen container or tanker weight bill to facilitate application at proper viscosity. 5.3.2 Flashing Design Principles. Good flashing design requires the following:
a) Elimination of as many penetrations as practical; b) Location of individual roof penetrations at least 18 inches (457 millimeters) apart; 18 SLOPE (inches per foot (percent) BITUMEN TYPE SOFTENING POINT (degrees F (C)) 1/2 (4) or less Asphalt, ASTM D 312, Type I 135 - 151 (57 - 66) 1/2 to 1-1/2 (4 to 12) Asphalt, ASTM D 312, Type II 158 - 176 (70 - 80) 1 to 3 (8 to 25) Asphalt, ASTM D 312, Type III 185 - 205 (85 - 96) Steep and flashings Asphalt, ASTM D 312, Type IV 205 - 225 (96 - 107) 1/4 (4) or less Coal Tar Pitch, ASTM D 450 Type I 126 - 140 (52 - 60) 1/2 (4) or less Coal Tar Pitch, ASTM D 450 Type III 133 - 147 (56 - 64)