Downloaded from https://www.everyspec.com MIL-HDBK-1001/5A c) Hazards of excess insulation thickness. 10.4.3 Membrane System. (Refer to par. 10.2 for reroofing steep roofing) In making a selection of membrane system, consider the following: a) Ponding water conditions, slow draining roofs, and potential formation of ice; b) Minimum slope restrictions.
Standard is 1/4 inch per foot (2 percent) for reroofing; c) Special construction logistics; d) Weight limitation dictated by existing deck; e) Expansion and/or control joint requirements; f) Flashing requirements; g) Fire and wind requirements; h) Roof traffic requirements; i) Maintenance requirement; j) Susceptibility to vandalism; k) Materials past performance record; 1) Product availability of all components from one manufacturer; m) Product compatibility with adjacent roofing products and materials within the new roof composite; n) Method of attachment; o) Tensile or "T" peel strength requirements, especially lap seams of single-ply systems; p) Cost. 10.4.4 Surfacing 44