Downloaded from https://www.everyspec.com MIL-HDBK-1001/5A GLOSSARY Aggregate. Gravel, crushed stone, washed round river gravel slag or mineral granules either (a) embedded in a conventional built- up membrane's bituminous flood coat, or (b) laid on a membrane as a protective ballast. Crushed stone should be avoided if possible. Alligatoring. Deep shrinkage cracks, progressing down from the surface, in smooth-surfaced membrane coatings and sometimes in bare spots of aggregate-surfaced membranes, a consequence of photo-oxidative hardening, shrinkage due to loss of aromatics. Asphalt.
A dark brown to black, highly viscous, hydrocarbon produced from the residuum left after the distillation of petroleum, used as the waterproofing agent of built-up roofs and other building components. Atactic polypropylene. High molecular-weight, thermoplastic, amorphous polymers used as a chemical ingredient to improve flexibility, elasticity, and ductility of bitumen, used in some single-ply modified bitumen membranes for torching applications. Backnailing. Slippage-preventing technique of "blind" (i.e., concealed) nailing in addition to hot-mopping. Ballast.
Aggregate, concrete pavers, or other material designed to prevent wind uplift or flotation of a loose-laid roof or insulation system. Aggregate should be smooth, round, without flat faces and sharp edges. Base Flashing. See Flashing. Base ply. A felt or mat, usually coated, placed as the first non-shingled ply in a multi-ply built-up roof membrane. Batten. Narrow metal or wood band used to anchor a membrane against wind uplift. Bitumen. Generic term for an amorphous, semisolid mixture of complex hydrocarbons derived from petroleum or coal. In the roofing industry there are two basic bitumens: asphalt and coal- tar pitch.
Before application, they are either (l) heated to a liquid state, (2) dissolved in a solvent, or (3) emulsified. Blindnailing. Nailing of felts with nail heads covered by overlapping top felts. 68