Super Micro Computer, Inc. SC513 — Super Micro SC513 Chassis Manual: Comprehensive Guide for System Integrators

Chapter 5: Chassis Setup and Maintenance System Fan Tray Replacement Removing the System Fan Tray Power-down the system and remove the chassis from any power source. 1. Disconnect each fan from the motherboard. 2. Carefully lift the air shroud's tabs out of the mounting holes on each side of 3. the system fan tray. Remove the three screws securing the system fan tray to the floor of the 4. chassis, setting aside the screws and rubber grommets for later use. Lift the system fan tray up and out of the chassis. 5. Replacing Individual System Fans Fans can be replaced individually without removing the system fan tray. There is no need to power down the system when replacing a system fan.

Replacing System Fans If necessary, open the chassis while the power is running to determine which 1. fan has failed. (Never run the server for an extended period of time with the chassis open.) Remove the failed fan's power cord from the serverboard. 2. Lift the failed fan completely from the chassis. 3. Place the new fan into the vacant space. Make sure the arrows on the top of 4. the fan (indicating air direction) point in the same direction as the arrows on the other fan(s). Confirm that the fan is working properly and replace the chassis cover.. 5. Installing the System Fan Tray Align the three mounting tabs on the system fan tray with the mounting holes 1.

on the floor of the chassis, placing the rubber grommets previously set aside between the chassis and the system fan tray. Secure the system fan tray to the floor of the chassis using the screws pro­ 2. vided. 5-13