SC513 Chassis Manual 6-4 Rack Mounting Instructions This section provides information on installing the SC513 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. NOTE : The SC513F-280/350/410/520/600 chassis models are designed with a wider chassis. The rails for these chassis will fit a rack between 25.6" and 33.05" deep. The following shows how to mount these chassis to a standard rack. The chassis package includes two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis, and an outer fixed rack rail that secures directly to the rack itself.The SC513F comes with "chassis handles", which allow the chassis to be mounted on generic rails. Identifying the Sections of the Rack Rails (Optional Item) Outer rai Short Bracket Attach to Front of Rack Figure 6-1: Identifying the Sections of the Rack Rails (Right side rail shown) 6-4 Inner Rail Attach to Chassis Short and long Brackets. Long Bracket Attach to Rear of Rack