SC523 Chassis Manual Chapter 4: System Interface 3. Verify that the heatsinks are installed properly. 4. If the chassis cover is not aligned correctly, the airflow may be disrupted. This leads to overheating. Confirm that the chassis cover is placed correctly. Reset: The reset button is used to reboot the system. 4-3 Control Panel LEDs The control panel located on the front of the SC523 chassis has six LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any correc- tive action you may need to take. NIC2: Indicates network activity on GLAN2 when flashing. ! NIC1:
Indicates network activity on GLAN1 when flashing. Power Failure: When this LED flashes, it indicates a power failure in the power supply Overheat/Fan Fail When Flashing: This LED indicates a fan failure. When Continuously On (not flashing). This LED indicates an overheat condition caused by cables obstructing the airflow in the system or the ambient room tem- perature being too warm. To correct this condition, do the following: HDD: Indicates IDE channel activity, SAS/SATA drive, and/or DVD-ROM drive activity when flashing. Check the Following Power: The main power switch is used to activate or deactivate power to the server system.
Turning off the system power with this button removes the main power, but standby power remains on. Therefore, you must unplug system before servicing. 1. Check the routing of the cables and move any cables that restrict the airflow. 2. Confirm that all fans are operating normally. 4-2 4-3