Supermicro SC745 — Releasing the Inner Rails

Chapter 2 Rack Mount Installation 2.4 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. Do not use a two post "telco" type rack. This rail set fits a rack between 26" and 35.9" deep. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided. You should also refer to the installation instructions that came with the specific rack you are using. Identifying the Rails The optional rackmount kit includes two rack rail assemblies, one for each side. Each of these assemblies consist of several sections:

an inner fixed rail that secures to the chassis, an outer rack rail that secures to the rack, a middle rail that slides within the outer rail, and two brackets that attach the outer rail to the rack. The brackets are specific to the left and right side, and front and back, and labeled. Outer rail Inner rail Rail brackets Figure 2-2. Identifying the Sections of the Rack Rails Releasing the Inner Rails The inner rails must be removed from the outer rails to install onto the chassis. To remove the inner rail, pull it out as far as possible until it clicks to a stop. Depress the locking lever on the inner rail next to the middle rail to pull the inner rail completely out. 17