Supermicro SC745 — 2.5 Installing the Server into the Rack

Chassis SC745 User's Manual 2.5 Installing the Server into the Rack After attaching rails to both the chassis and the rack, slide the server into the rack. 1. Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail. 2. Align the rear of the inner (chassis) rails with the front of the outer (rack) rails and slide the inner rails into the outer rails until the server is completely in the rack. 3. Insert and tighten the thumbscrews that hold the front of the server to the rack. Figure 2-5. Installing the Server into a Rack Note: Figure is for illustrative purposes only.

Always install servers to the bottom of a rack first. Warning: Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over. When initially installing the server to a rack, test that the rail locking tabs engage to prevent the server from being overextended. Have a rack lift in place as a precaution in case the test fails. 20