Supermicro SC812L — Supermicro SC812L Chassis Manual: User & Service Guide PDF Download

Chapter 4: Chassis Setup and Maintenance The Left Blower is turned toward the rear of the chassis Foam Barrier Foam Barrier The Right Blower is angled to the side Figure 4-8: System Blowers in default position Blower Default Position With most compatible SuperMicro motherboards, the blowers remain in the default position. The default position is the tray in the furthest right position. The left blower is directed toward the rear of the chassis. The right blower is turned to the left. Blower Secondary Position motherboard with an AMD CPU, do the following: The following only applies to non-"U" brand chassis. When using a SuperMicro 1.

Disconnect the blowers from the motherboard and remove the foam barrier from the chassis. 2. Move the rack one position to the left. 3. Remove the right blower and turn it so that it points directly toward the rear of the chassis. 4. Confi rm that the fi rst blower is also turned toward the rear of the chassis. 5. Replace the foam barrier using the foam from the accessory box. This foam is especially measured for the secondary blower position. 4-9