Supermicro SC815 — The Inner Rail Extension (Optional)

SC815 Chassis Manual Chapter 6 Rack Installation 6-4 Rack Mounting Instructions This section provides information on installing the SC815 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the instal- lation instructions that came with the rack unit you are using. 2 NOTE: This rail will fit a rack between 26" and 33.5" deep. Identifying the Sections of the Rack Rails 1 The chassis package includes two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections:

an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Inner Rail Extensions (Optional) Figure 6-2. Identifying the Sections of the Rack Rails (right side rail shown) The Inner Rail Extension (Optional) The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use a server rack. Attach the inner rail extension to stabilize the chassis within the rack. If you are not using a rack, you do not have to install the inner rail extensions. Installing the Inner Rails Rail Locking Tabs 1.

Place the inner rack extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the pre-attached inner rail. Front Inner Rails (Inner Rail is preinstalled on the chassis) 2. Slide the extension toward the front of the chassis. Figure 6-1. Identifying the Sections of the Rack Rails 3. Secure the chassis with two screws as illustrated. Repeat steps for the other inner rail extension. Locking Tabs Both chassis rails have a locking tab. The tabs lock the server into place when installed and pushed fully into the rack. These tabs also lock the server in place when fully extended from the rack.

This prevents the server from coming completely out of the rack when you pull it out for servicing. Warning: do not pick up the server by the front handles. They are designed to pull the system from a rack only. 6-4 6-5