Supermicro SC825M(B) — Supermicro SC825M(B) Chassis Manual: 2U Short-Depth Server Rack System

SC825M(B) Chassis Manual 4-2 Control Panel Buttons The chassis includes two push-buttons that control power to the system. Reset : The reset button is used to reboot the system. Power : The main power switch is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. Therefore, you must unplug system before servicing. 4-3 Control Panel LEDs There are six LEDs that provide status information about the system. ! Power Failure : When flashing, this LED indicates a power supply failure. Information LED : Alerts operator of several states, as noted in the table below.

4-2 Information LED Status Description Continuously on and red An overheat condition has occurred. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location.