Supermicro SC825M(B) — Supermicro SC825M(B) Chassis Manual: 2U Short-Depth Server Rack System

SC825M(B) Chassis Manual 5-10 System Fans The 825M(B) chassis includes four fans for cooling and air circulation. A dummy fan is included as a place holder. System Fans Rubber Fan Feet Dummy Fan Figure 5-19. System Fan and Dummy Fan in Fan Tray Note: The 825M(B) chassis includes four pre-installed fans. An extra slot is included for an optional fifth fan. Replacing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan needs replacing. (Never run the server for an extended period of time with the chassis open.) 2. Power down the system and remove the power cord from the back of the power supply module as described in Section 5-2.

Remove the chassis cover as described in Section 5-3. 3. Remove the hard drive housing and DVD drive assembly (if equipped). For instructions on doing this, see the section of this chapter on Installing the Motherboard . 4. Disconnect the fan from the motherboard and lift the fan from the fan tray. 5-18