Appendix C Backplane Specifications Failover with RAID Cards and Multiple HBAs The BPN-SAS2-836EL backplane may be configured for failover with multiple HBAs using either RAID controllers or HBAs to achieve failover protection. RAID Controllers: If RAID controllers are used, the failover is accomplished through port failover on the same RAID card. HBAs : If multiple HBAs are used to achieve failover protection and load balancing, Linux MPIO software must be installed and correctly configured to perform the load balancing and failover tasks. Dual Host Bus Adapter SAS HBA In a dual host bus configuration, the backplane connects to two HBAs.
SAS HBA SEC_J0 SEC_J1 SEC_J2 PRI_J1 PRI_J2 Port B Port A PRI_J0 Expander 2 Expander 1 Figure 2EL-7. Dual HBA SAS HBA Dual Host Bus Adapter Failover If the expander or data path in Port A fails, the system automatically switches to Port B. This maintains a full connection to all drives. SAS HBA Port B SEC_J0 SEC_J1 SEC_J2 PRI_J1 PRI_J2 Port A PRI_J0 Expander 2 Expander 1 Figure 2EL-7. Dual HBA Failover IMPORTANT: For RAID controllers, redundancy is achieved through port failover. For multiple HBAs MPIO software is required to achieve failover protection. C-29