SC846 Chassis Manual Overheating There are several possible responses if the system overheats. Overheat Temperature Setting Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by changing a jumper setting. For more information, consult the backplane user manual at www.supermicro.com. (Click Support, then the Manuals link.) Responses If the server overheats: 1. Use the LEDs to determine the nature of the overheating condition. 2. Confirm that the chassis covers are installed properly. 3. Check the routing of the cables and make sure all fans are present and operating normally. 4. Verify that the heatsinks are installed properly.
3-4 Drive Carrier LEDs The chassis includes externally accessible SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. 3-4 LED Color Blinking Pattern Behavior for Device Activity LED Blue Solid On SAS/NVMe drive installed Blue Blinking I/O activity Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuild drive with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for drive with RSTe support Red On for five seconds, then off Power on for drive with RSTe support Red Blinking at 4 Hz Identify drive with RSTe support