Supermicro SC846X — Supermicro SC846X Chassis User's Manual (4U) – Free PDF Download

SC846X Chassis Manual 4-8 System Fans Four hot-swappable, heavy-duty fans provide cooling from the middle of the chassis, augmented by one rear exhaust fan. Two optional rear external fans can be mounted to help cool expansion cards. Mid-Chassis and Internal Rear Fans Release Tab Indicator Release Tab Airflow Direction Mid-chassis Fan Internal Rear Fan Figure 4-16. System Fans Replacing a System Fan 1. Use IPMI or another monitoring tool, if available, to determine which fan has failed. 2. Open the chassis cover. If a monitoring tool is not available, observe which fan has failed. (Never run the server for an extended period of time with the chassis cover open.) 3.

Remove the failed fan's power cord from the serverboard. 4. Press the fan release tab to lift the failed fan from the chassis and pull it completely out of the chassis. 5. Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating airflow direction) point in the same direction as the arrows on the other fans. 6. Check that the fan is working properly before replacing the chassis cover. 4-16