Supermicro SC847DJ — Super Micro SC847DJ Chassis Manual PDF Download

SC847DJ Chassis Manual F-14 Control Panel LEDs The control panel is located on the left handle of the SC847DJ chassis and has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 1 NIC1: Indicates network activity on GLAN1 when flashing. Information LED: F-14 Informational LED Status Description Solid red An overheat condition has occured. (This may be caused by cable congestion).

Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue (300 msec) Remote UID is on. Use this function to identify the server from a remote location. Blinking blue (500 msec) System is ready to power up. See Section 4-4 of this manual.