Supermicro SC936E16-R1200B — Supermicro SC936E16-R1200B Chassis Manual: 3U Server with Hot-Swappable Drives

Appendix E: BPN-SAS2-936EL Backplane Specifications E-11 Failover with RAID Cards and Multiple HBAs The BPN-SAS-936EL backplane may be configured for failover with multiple HBAs using either RAID controllers or HBAs to acheive failover protection. RAID Controllers: If RAID controllers are used, then the failover is accomplished through port failover on the same RAID card. HBAs : If multiple HBAs are used to achieve failover protection and load balancing, Linux MPIO software must be installed and correctly configured to perform the load balancing and failover tasks. Dual Host Bus Adapter In a dual host bus configuration, the backplane connects to two host bus adapters.

SAS HBA SAS HBA Q3 + EC5 U18 A C ACT18 SEC_MODE1 SEC_MODE2 3 3 EXPDBG2 + C365 + + C366 C363 + EC26 L2 L1 + C91 C133 C120 + C128 MDIO1 + JP1 BUZZER_ENB1 1 4 1 SEC_J0 SEC_J2 MH9 J18 1 1 4 UART_S1 J19 SEC_J2 A MDIO2 1 4 MH5 MH6 MH7 MH8 5 20 10 15 25 U4 E C361 K R Y AE C367 AH + + + C362 SEC_J0 + R6 EC27 SAS2-936EL2 REV:

1.01 PRI_J0 PRI_J2 SEC_J1 EC4 EC1 SEC_J1 + + EC2 PRI_J2 Q4 BCA84 WWN BAR CODE + U3 5 20 10 15 25 28 1 E 4 UART_P1 K L59 4 EXPDBG1 R Y AE AH C76 C67 C121 1 + C119 C134 C132 + J16 2 1 PRI_J0 PRI_J1 5V_LED1 OVERHEATFAIL1 12V_LED1 FANFAIL1 ACT17 A C A C A C 1 PRI_J1 FANFAIL_LED_DISABLE A C A C 1 ACTLED1 1 PRI_MODE1 1 PRI_MODE2 U13 3 PRI_I2C1 1 FAN_MONITOR_DISABLE + MH13 GND GND +12V +5V +5V +12V GND GND PWR1 +5V +12V GND GND EC20 PWR4 + +5V +12V GND GND PWR3 + Port A Expander 1 Port B Expander 2 PWR2 C390 + EC16 + MH12 EC17 + 4 1 FAN1 + EC14 EC11 + EC13 MH10 MH11 + EC8 4 1 FAN2 EC10 4 1 FAN3 + EC9 Dual Host Bus Adapter Failover If the expander or data path in Port A fails, the system will automatically fail over to Port B.

This maintains a full connection to all drives. SAS HBA SAS HBA Q3 + EC5 U18 A C ACT18 SEC_MODE1 SEC_MODE2 3 EXPDBG2 + C365 + + + C366 C363 + EC26 L2 L1 + C91 C133 C120 + C128 MDIO1 + JP1 BUZZER_ENB1 1 4 1 SEC_J0 SEC_J2 MH9 J18 1 1 4 UART_S1 J19 SEC_J2 A MDIO2 3 1 4 MH5 MH6 MH7 MH8 5 20 10 15 25 U4 E C361 K R Y AE C367 AH + + C362 SEC_J0 + R6 EC27 SAS2-936EL2 REV:

1.01 PRI_J0 PRI_J2 SEC_J1 EC4 EC1 SEC_J1 + + EC2 PRI_J2 Q4 BCA84 WWN BAR CODE + U3 5 20 10 15 25 28 1 E 4 UART_P1 K L59 4 EXPDBG1 R Y AE AH C76 C67 C121 1 + C119 C134 C132 + J16 2 1 PRI_J0 PRI_J1 5V_LED1 OVERHEATFAIL1 12V_LED1 FANFAIL1 ACT17 A C A C A C 1 FANFAIL_LED_DISABLE A C A PRI_J1 C 1 ACTLED1 1 PRI_MODE1 1 PRI_MODE2 U13 3 PRI_I2C1 1 FAN_MONITOR_DISABLE + MH13 GND GND +12V +5V +5V +12V GND GND PWR1 +5V +12V GND GND EC20 PWR4 + +5V +12V GND GND PWR3 + Port A Expander 1 Port B Expander 2 PWR2 C390 + EC16 + MH12 EC17 + 4 1 FAN1 + EC14 EC11 + EC13 MH10 MH11 + EC8 4 1 FAN2 EC10 4 1 FAN3 + EC9 IMPORTANT: For RAID controllers, redundancy is achieved through port failover.

For multiple HBAs MPIO software is required to achieve failover protection. E-11