b) Digital signal distribution mode is parameter configuration (Pn600=1 default parameter). *1: The enabled method of the Digital zero-position clamp signal (/ZCLAMP) must be used in conjunction with the parameters Pn312 and Pn313. Refer to the description of the function code. 5.6 Other Output Signals 5.6.1 Servo Ready Output Signal The servo ready output signal (/S-RDY) is a indicate signal that the servo unit can receive servo ON (/S-ON) signals and command signals. This signal is output under the following conditions:  The main circuit power is on. For details on the output timing of /S-RDY during power-on, see “Power-up enable ON timing”.  Non-hardwired base blocking status.

 No alarm occurred.  When using an absolute encoder, the SEN signal turns ON (H level). 1) Parameter configuration of servo-ready In the factory default digital output configuration, the signal is configured as CN1 25, 26 pin (Pn613=0x00) by default. Please confirm before use. The servo ready signal is a general configurable Digital output. See “Sequence Output Circuit” for wiring details. 2) Wiring of servo ready 5.6.2 Warning Output Signal The warning output signal (/WARN) is a warning function before the alarm, which makes it easier for the host device to judge the operation of the servo unit in advance. For detailed warning code, please refer to “Warning Code”.

1) Configuration of warning output signals This signal is not configured in the factory default Digital output configuration. The pin number 107 SD700 Series Servo Technical Manual Digital input signal Pn000 Setting 10 11 /ZCLAMP (parameter configuration) ON Speed mode with zero fixed function (*1) - OFF Speed mode - /INHIBIT (parameter configuration) ON - Position mode with command pulse inhibit function OFF - Position control