VEICHI — SD700 User Manual 20230516

8.3.3 Home Position Return Method 3 a. Start the home position return → home position signal is OFF → search for the rising edge of home position signal at high speed forward direction → decelerate to 0 → search for the falling edge of home position signal at low speed reverse direction → search for Z pulse in reverse direction. Forward direction 3-a Home position Motor signal Running route H -L -H Home position signal Z pulse b. Start the home position return → Home position signal ON → Search for the falling edge of home position at low speed reverse direction → search for Z pulse in reverse direction.

Home position return method 3-a Forward direction 3-b Home position return method 3-b Z pulse 161 SD700 Series Servo Technical Manual Home position signal Motor -H Running route -L Hom position Z