VEICHI — SD700 User Manual 20230516

8.3.7 Home Position Return Method 7 a. Start the home position return →Home position signal OFF →Search for the rising edge of home position at high speed forward direction →Decelerate to 0 →Search for the falling edge of home position at low speed reverse direction →Search for the Z pulse in reverse direction. Forward direction 7-a Z pulse Home position return method 7-a b.Start the home position return →Home position signal ON →Search for the falling edge of home position at low speed reverse direction →Search for the Z pulse in reverse direction.

Forward direction 7-b Z pulse Home position return method 7-b 165 SD700 Series Servo Technical Manual Motor Home position signal Limit signal H ning route -L -H Ho positio Limit Home position signal Motor Limit signal Running route -H -L Home p sig Z Limi