VEICHI — SD700 User Manual 20230516

c.Start the home position return →Home position signal OFF →Search for the rising edge of home position at high speed reverse direction →Touch the reverse limit →Search for the falling edge of home position at high speed forward direction →Decelerate to 0 →Search for the rising edge of home position at low speed reverse direction →Search for the Z pulse in forward direction.

Forward direction 11-c Z pulse Home position return method 11-c 8.3.12 Home Position Return Method 12 a.Start the home position return →Home position signal OFF →Search for the rising edge of home position at high speed reverse direction →Decelerate to 0 →Search for the falling edge of home position at low speed forward direction →Search for the rising edge of home position at low speed reverse direction →Search for the Z pulse in reverse direction. Forward direction 12-a Z pulse Home position return method 12-a 173 SD700 Series Servo Technical Manual Motor Limit signal Home position signal -H Running route H L H Limit signal Home position Motor signal L -H