12 Fault Code and Countermeasures 12.1 Fault Code 262 SD700 Series Servo Technical Manual Fault Fault type Solutions Alarm code category Er.020 Abnormal parameter and check 1. Enter the parameters again after initializing parameter settings. 2. Write the power level of the driver to 0 first, and then write the correct power level. Note: Remember to perform the current detection correction, analog input correction and bus voltage correction after writing the power level. 3. servo driver failure, replace the servo drive. Category 1 Er.021 Parameter formatting exception (inconsistent version number) 1. Perform a soft reset.
If the fault is still reported, write the driver's power level to 0 and then write the correct power level. Note: Remember to perform the current detection correction, analog input correction and bus voltage correction after writing the power level. 2. servo driver failure and replace the servo drive. Category 1 Er.022 Abnormal system and check 1. Perform a soft reset. If the fault is still reported, write the driver's power level to 0 and then write the correct power level. Note: Remember to perform the current detection correction, analog input correction and bus voltage correction after writing the power level. 2. servo driver failure and replace the servo drive.
Category 1 Er.030 Abnormal detection in main circuit 1. Servo driver fails, replace the servo driver. Category 1 Er.040 Abnormal parameter setting 1. Check whether the changed parameters are out of range. 2. Check if the setting of electronic gear ratio is within the setting range (electronic gear ratio: 0.001~16777216/1000). 3. Check whether the servo drive and servo motor capacity match. 4. I/O terminal definition repeat. Category 1 Er.041 Abnormal frequency division pulse output setting According to the number of encoder bits, the number of encoder frequency division pulses is set to an appropriate value, see the specification. Category 1 Er.042 Abnormal parameter combination 1.
Make the setting value of electronic gear ratio within the setting range. 2. make the program JOG settings related to logic. Category 1 Er.044 Abnormal setting of loop parameters 1. Set the half closed loop / full closed loop parameters correctly. Category 1 Er.050 Unmatched drive and motor capacity 1. check if the driver power and motor power are correct. 2. replace the drive or motor so that it is within a reasonable range. Category 1 Er.051 Alarm caused by product technical support failure 1. Connect the function modules can not be supported by the product, please select the matching combination. Category 1 Er.080 Abnormal distance setting corresponding to unit pulse of 1.
Correctly set the distance corresponding to the unit pulse of the encoder. Category 1