VEICHI — SD700 User Manual 20230516

the slave responds with the corresponding function code and data address or sub-function code. In response to the objection, the device returns a code equivalent to the normal code, but the first position is logic 1. For example, if a message sent by a master device to a slave device requires reading a set of servo driver function code address data, the following function code will be generated: 0 0 0 0 0 0 1 1 (hex 03H) For a normal response, the slave responds with the same function code. In response to the objection, it returns:

1 0 0 0 0 0 1 1 (hexadecimal 83H) In addition to the modification of the function code due to an objection error, the slave device will respond with a one-byte exception code, which defines the cause of the exception. After the master application responds with an objection, the typical process is to resend the message or make a command change for the corresponding failure.

272 SD700 Series Servo Technical Manual Modbus exception code Code Name Meaning 01H Illegal function When the function code received from the host computer is an operation that is not allowed, this may be because the function code is only applicable to the new device and is not implemented in the device; at the same time, the slave may also process the request in an error state. 02H Illegal data address For the servo drive, the request data address of the upper computer is an unallowable address; in particular, the combination of the register address and the transmitted byte number is invalid.

03H Illegal data value The received data value exceeds the range of the address parameter, causing the parameter change to be invalid. 11H Parity error When the RTU format CRC check bit or the ASCII format LRC check bit is different from the check calculation number of the lower computer in the frame information sent by the host computer, the check error information is reported.