B/C/D-volume three-phase wiring diagram MC 39 SD700 Series Servo Technical Manual ON OFF ALM Please make this emergency stop protection circuit. Electromagnetic contactor package surge absorbing dev Breaker at both ends. EMI L1 MC filter L2 220V system input voltage range: AC 220V(-15%)~240V(+10%) L3 400V system input voltage range: A C 380V(-15%)~440V(+10%) L1C L2C B1/+ Please connect the U, V, W, and output of the drive B2 correctly according to the motor cable phase sequence o the servo motor. The wrong phase sequence will cause t B3 drive to malfunction. Motor Do not disconnect short wires between B2 and B3 unles - using an external regenerative braking resistor.
When using an external regenerative braking resistor, U disconnect the short wiring between B2 and B3 and connect them by the dotted line in the figure. V W Yellow / green Emergency button Be sure to ground the servo drive to avoid electrical dam Surge /S-RDY absorber DC 24V± 10% Fuse CN1 The 24V power supply for electromagnetic braking need to be provided by the user and must be isolated from the ALM+ DC 12V~24V ALM 12V~24V power supply for the control signal. Pay attention to the connection of the freewheeling diod (± 10%) Reserving the positive & negative poles may damage th ALM- Please make this emergency stop protection circuit.
Electromagnetic contactor package surge absorbing dev at both ends. EMI filter MC