VEICHI — SD700 User Manual 20230516

The field identification bit E is M:MECHATROLINK-II bus type. The field identification bit E is E:EtherCAT bus type;L: MECHATROLINK-III bus type; N: PROFINET bus type. As for using multiple drivers at the same time, the cascade mode is CN6A in and CN6B out. Failure to follow the cascade mode of up in and down out may lead to abnormal communication. Please try to ensure that the length of the cascaded cable is less than 50cm, and the CN6B of the last one should be connected with the terminal resistance (Only CANopen bus/ Mechatrolink-II bus/ RS-485 bus should be considered with terminal resistance).

3.7 CN5 Full Closed Loop Port 48 SD700 Series Servo Technical Manual 5 485+ 485 Data + CN6A/CN6B port definition Pin No. Signal name Function Pin No. Signal name Function 1 SRD+ M-II Data + 6 - - 2 SRD- M-II Data - 7 - - 3 - - 8 - - 4 - - Shell Shield Shield 5 - - CN6A/CN6B port definition Pin No. Signal name Function Pin No. Signal name Function 1 TX+ Data transmission+ 6 RX- Data reception - 2 TX- Data transmission- 7 - - 3 RX+ Data reception + 8 - - 4 - - Shell Shield Shield 5 - - 2500 line encoder and full closed loop port (differential input) Pin No. Signal name Function Pin No. Signal name Function 1 EA- Full closed loop signal EA- 9 - - 2 EB- Full closed loop signal EB- 10 - -