VEICHI — SD700 User Manual 20230516

The upper SEG (LED) lights up when the output signal is OFF. The lower SEG (LED) lights up when the output signal is ON. The value read through communication is hexadecimal, for example: the read value is 0X8, and the default output configuration means that ALM (CN1-31, 32) output is ON, that is, no alarm output. /S- RDY (CN1-25, 26) output is OFF, that is servo ready. /COIN (CN1-27, 28) output is OFF, that is positioning is completed. / V-CMP (CN1-29 / 30) output is ON, and the speed is not consistent. 3.11 Connection with the Upper Device 3.11.1 Analog Input Circuit The following describes the 5-6 (speed command input) and 9-10 (torque command input) terminals of the CN1 connector.

Analog signals are speed commands or torque command signals. The input impedance is as follows. Speed command input: about 66kΩ. Torque command input: about 66kΩ. The maximum allowable input signal voltage is ± 10V. Controller Servo drive The above wiring is an example of wiring during forward rotation. 3.11.2 Position Instruction Input Circuit The following describes the 7-8 (command pulse input), 11-12 (command symbol input), and 14-15 (clear input) terminals of the CN1 connector.

The output circuit of the command pulse and position deviation clear signal from the host device may be one of the linear driver output and the open 57 SD700 Series Servo Technical Manual 2 CN1-25、26 /S-RDY 3 CN1-27、28 /COIN 4 CN1-29、30 /V-CMP Connect the sh according to th 5 V-REF About 66kΩ GND T-REF About 66kΩ GND FG Twisted p ai 6 r 9 10 ield wire e requirements