2.Control modules is PNP type (common anode): ! If the linear drive input port is used to receive the external 24 V collector open circuit input signal, connect a 2k resistor in series to limit the current in the circuit, otherwise, the linear drive input port will be damaged. Cautions 59 SD700 Series Servo Technical Manual Y0 Y1 Y2 Twisted Shield pair 16 wire 8 OCP PULSE 2kΩ /PULSE OCS SIGN 2kΩ /SIGN OCC CLR 2kΩ /CLR FG Drive side wire 8 17 12 Y2 24 14 24V Control module side Y0 Y1 Y2 Control module Shield wire Twisted wire 16 OCP PULSE 2kΩ /PULSE OCS SIGN 2kΩ /SIGN OCC CLR 2kΩ /CLR FG Drive 8 17 12 24 14 24V 8 17 Y2 12 24 14