3.17 Circuit Breaker If residual current operated protective device (RCD) is to be used for the equipment, please select the type according to the following conditions: ● The drive equipment can generate DC leakage current in the protective conductor. Please be sure to use type B residual current operated protective device (RCD). ● When the drive is running, it will generate certain high-frequency leakage current. In order to avoid RCD misoperation, please select RCD with an operating current of not less than 100mA for each drive. ● When multiple drives are connected in parallel to share one RCD, select an RCD with an action current of not less than 300mA.
● We recommend to use RCD of Chint (正泰) , Schneider (施耐德 or other brands. 68 SD700 Series Servo Technical Manual Servo drive Recommended circuit breaker Drive model Rated input Manufacturer Rated Model No.
current(A) current (A) Single-phase 230V SD700-1R1A 1.28 Schneider Electric 6 OSMC32N2C6 SD700-1R8A 2.1 Schneider Electric 6 OSMC32N2C6 SD700-3R3A 3.89 Schneider Electric 6 OSMC32N2C6 Three-phase 230V SD700-5R5A 3.1 Schneider Electric 6 OSMC32N3C6 SD700-7R6A 4.2 Schneider Electric 16 OSMC32N3C16 SD700-9R5A 5.2 Schneider Electric 16 OSMC32N3C16 SD700-120A 10.3 Schneider Electric 16 OSMC32N3C16 SD700-160A 13.7 Schneider Electric 20 OSMC32N3C20 Three-phase 400V SD700-2R5D 2.8 Schneider Electric 4 OSMC32N3C4 SD700-3R8D 4.18 Schneider Electric 6 OSMC32N3C6 SD700-6R0D 8.8 Schneider Electric 6 OSMC32N3C6 SD700-8R4D 12.4 Schneider Electric 16 OSMC32N3C16 SD700-110D 16.2 Schneider Electric 16 OSMC32N3C16 SD700-170D 22.4 Schneider Electric 16 OSMC32N3C20 SD700-240D 31.6 Schneider Electric 25 OSMC32N3C25 SD700-300D 39.5 Schneider Electric 32 OSMC32N3C32 SD700-500D 46.7 Schneider Electric 50 OSMC32N3C50 SD700-600D 56 Schneider Electric 63 OSMC32N3C63