In terms of resistance to electromagnetic influences and the level of radiated radio interference, the device corresponds to class A equipment in accordance with GOST 51522-1999 (IEC 61326-1). In terms of resistance to mechanical influences during operation the device corresponds to group of performance N2 in GOST R 52931-2008. According to the resistance to climatic impacts during operation, the device corresponds to the execution group V4 according to GOST R 52931-2008. NOTICE Requirements in terms of external influencing factors are mandatory as related to safety requirements. 3 Security measures CAUTION There is life-threatening voltage of up to 250 V on terminal block.
Any connections to the device and maintenance work should be carried out only when the device power is turned off. By the method of protection from electric shock the device corresponds to class II according to GOST12.2.007.0-75. While operating, maintaining and checking, it is necessary to comply with GOST 12.3.019-80, Rules ofthe technical operation of electrical consumers and Safety rules for operating electrical equipment. Do not allow moisture to contact the output connector and the internal electrical elements of the device. It is forbidden to use the device in corrosive environments containing acids, alkalis, oils, etc. in the atmosphere. 10