СИ20 — 7.1 Sequence of setup

point of the entered multiplier), editing of parameters FDP , DP , F should be performed in the following sequence: • to increase the number of displayed digits after the decimal point (decimal point offset to the left): ◦set parameter FDP ; ◦set parameter F ; ◦set parameter DP . • to decrease the number of displayed digits after the decimal point (decimal point offset to the right): ◦set parameter DP . ◦set parameter FDP ; ◦set parameter F . Due to the restrictions imposed by the Dispenser mode ( oUt = 2 ), it is recommended to change the mode of operation of the control unit in the following sequence: • set parameter SPM ; • set parameter rSt ; • set parameter oUt .

NOTICE The list of configurable parameters of the device and their possible values is shown in Appendix A A . 36