Smart IP43 Charger 4.4. VE.Smart networking The Smart IP43 Charger range feature VE.Smart networking capability, which enables Bluetooth communication between compatible Victron products to optimise charger operation and battery performance/life. This powerful feature enables chargers to receive accurate battery voltage ( Volt-sense ), charge current ( Current-sense ) and battery temperature ( Temp-sense ) data from a compatible battery monitor (such as a BMV, SmartShunt, Smart Battery Sense or VE.Bus Smart Dongle) and/or multiple chargers to operate in unison with synchronised charging to further enhance the charge cycle.
A single compatible battery monitor (such as a BMV, SmartShunt, Smart Battery Sense or VE.Bus Smart Dongle) will provide voltage, temperature and/or current sense data to all (a single or multiple) chargers withing the common VE.Smart network . Multiple compatible chargers in a common VE.Smart network (with or without a battery monitor) will also synchronise their charge algorithm (known as synchronised charging). 1. Only one battery monitor (BMV, SmartShunt, Smart Battery Sense or VE.Bus Smart Dongle) can be included in a VE.Smart network . 2.
All battery monitor connections (voltage sensing cables, temperature sensor and current shunt) and chargers in a common VE.Smart network must be connected to the same battery / battery bank. 3. The maximum number of devices permitted in a VE.Smart network is 10. 4. Communication via VE.Smart networking requires all devices to be located within Bluetooth range of each other. Systems with poor or intermittent Bluetooth signal between devices will experience connection issues. Signal strength between devices can be checked in the VictronConnect VE.Smart networking page. 5.
Multiple chargers in a common VE.Smart network must have the same charge settings, since the master can change dynamically any charger could become the master. 6. Multiple chargers in a common VE.Smart network do not need to be the same type or model, they just need to be VE.Smart Networking compatible (this includes VE.Smart Networking compatible Blue Smart chargers, Smart IP43 chargers and MPPT solar chargers). 7. Some older devices may not be VE.Smart networking compatible or have limitations; refer to the VE.Smart Networking Product Compatibility table in the VE.Smart Networking manual to confirm.
Voltage Sense uses battery voltage data that is accurately measured directly at the battery terminals (or very close) and provides it to the charger, the charger then uses this voltage data to dynamically increase the output voltage and precisely compensate for voltage drop in the cabling and connections between the charger and battery. 4.4.1. Voltage sense This enables the battery to be charged with the exact voltage as configured in the charger, instead of a lower voltage due to voltage drop in the cabling and connections.
Voltage drop is proportional to the charge current and cabling/connection resistance (V=IxR), so voltage drop will vary during a charge cycle and can be quite significant when charging at higher charge currents through cabling and connections with higher than optimal resistance; in this scenario voltage sense will be particularly beneficial. Note that voltage sense does not allow inadequately rated cabling/connections to be used or compensate for excessively high voltage drop; for reliable and safe operation cabling and connections must all be suitably rated and appropriately sized for the application; refer to the 'Installation > Wiring' section for more information.
Synchronised charging capability enables multiple compatible chargers to be combined together in a common VE.Smart network , allowing the chargers to operate in unison as if they were one large charger. 4.4.2. Synchronised charging The chargers will synchronise the charge algorithm between themselves with no further hardware or physical connections required, and simultaneously change charge states. Synchronised charging works by systematically prioritising all chargers and assigning one as the master, this charger then controls the charge stage of all other slave chargers.
In case the initial master is disconnected from the VE.Smart Network for any reason (out of Bluetooth range for example), another charger will be systematically reassigned as the master and take over control; this can also be reversed if communication with the initial master (that has a higher priority) is re-established. The master charger can not be manually selected. Synchronised charging does not regulate or equalise the current output of multiple chargers, each charger still has total control over it's own current output.
Accordingly, current output variation between multiple chargers is normal (primarily dependent on cable resistance and charging conditions) and a total system current output limit cannot be configured; when a total system current output limit is important, consider using a GX device with DVCC (Distributed Voltage and Current Control) instead of VE. Smart Networking . Page 11 Operation