Smart IP43 Charger 5. Installation 5.1. Mounting The Smart IP43 Charger range is designed to be permanently mounted using the mounting flanges integrated into the heat sink. Before mounting, the following aspects should be considered to identify/provide a suitable and safe location: A. Install the charger in a location with good natural airflow/ventilation; in case airflow is a restricted, consider adding a cooling fan. B. Ensure there is sufficient unobstructed space around the charger; a minimum clearance of 100mm above and below is recommended. C.
Install the charger on a non-flammable substrate and ensure there are no heat-sensitive items in the immediate vicinity; it is normal for the charger to become hot during operation. D. Install the charger in a location where it is protected from environmental conditions such as water, high moisture and dust, and also located well away from any flammable liquids or gasses. E. Do not install or place/operate the charger on top of the battery, directly above the battery, or in a sealed compartment with the battery; batteries can emit explosive gasses. F. Do not cover or place any other items on top of the charger. G.
The Smart IP43 Charger models 36/15 (1) and 48/13 (1) are intended for built-in installation. During installation ensure that: In a closed enclosure, a clearance of at least 100mm is maintained above and below the charger, and sufficient ventilation openings are provided to create an airflow path that lets cold air in and hot air out. A means of disconnection from the supply is provided after installation; this can be achieved by keeping the AC power cable plug accessible. The connection to the supply mains must comply with local and national wiring regulations.
Mount the Smart IP43 Charger vertically with the terminals facing down; secure using suitable screws though the mounting holes/slots. Select and use screws with a pan/flange head (do not use screws with a countersunk/tapered head), and a screw thread outer diameter well matched to the mounting hole/slot internal diameter (~5mm max OD to provide a clearance fit). To aid installation, it is recommended to hang the unit using the 2 upper screws (leave the screw heads ~3mm from the surface) and then install the 2 lower screws, before fully securing all 4 screws. Refer to the drawing below for mounting dimensions: Page 16 Installation