Smart IP43 Charger 5.3.3. System with multiple chargers Multiple chargers in parallel (with optional SmartShunt) Refer to the wiring schematic below to connect multiple Smart IP43 Chargers in parallel to a single battery / battery bank, with an optional SmartShunt or BMV battery monitor in the system: A B C D F E G H A VE.Smart Network must be setup between all Smart IP43 Chargers connected in parallel (and the optional SmartShunt or BMV battery monitor, if used) to enable Bluetooth connectivity and communication between devices; refer to the 'Advanced Configuration > VE.Smart Networking’ section for more information.
Page 27 Installation Key Description A AC power supply x2 (mains power grid, generator or inverter) B Smart IP43 Chargers x2 C Fuses / circuit breakers x2 (locate as close as practical to DC positive busbar) D DC positive and negative busbar E Fuse / circuit breaker (locate as close as practical to battery) F SmartShunt or BMV battery monitor shunt (SmartShunt/BMV is optional, locate as close as practical to battery) G Temperature and voltage sensor (Optional accessory, PN: ASS000100000) H Battery / battery bank